Are HEDP Corrosion Inhibitors resistant to high temperatures?

Posted on January 16, 2024January 16, 2024 By admin No Comments on Are HEDP Corrosion Inhibitors resistant to high temperatures?

HEDP (1-Hydroxyethylidene-1,1-Diphosphonic Acid) corrosion inhibitors generally exhibit good thermal stability and can withstand high temperatures to a certain extent. However, their performance and stability may vary depending on factors such as concentration, pH, duration of exposure, and specific application conditions. In general, HEDP is stable and effective in temperatures up to around 150-200°C (302-392°F). At…

Read More “Are HEDP Corrosion Inhibitors resistant to high temperatures?” »

Work

Are HEDP Corrosion Inhibitors soluble in alcohol?

Posted on January 16, 2024January 16, 2024 By admin No Comments on Are HEDP Corrosion Inhibitors soluble in alcohol?

HEDP (1-Hydroxyethylidene-1,1-Diphosphonic Acid) corrosion inhibitors are generally not highly soluble in alcohols. HEDP is most commonly soluble in water and has good solubility in other polar solvents like glycols and amines. Alcohols, on the other hand, have limited solubility with HEDP due to differences in their polarity and molecular interactions. While some low molecular weight…

Read More “Are HEDP Corrosion Inhibitors soluble in alcohol?” »

Work

Corrosion Inhibitors The role of ATMP in carbon steel

Posted on January 16, 2024 By admin No Comments on Corrosion Inhibitors The role of ATMP in carbon steel

ATMP (aminotris(methylenephosphonic) acid) plays a significant role as a corrosion inhibitor for carbon steel. Its effectiveness lies in its ability to form a protective layer on the surface of the metal, inhibiting corrosion and extending the lifespan of the carbon steel infrastructure. When ATMP is applied to carbon steel, it chemically adsorbs onto the metal…

Read More “Corrosion Inhibitors The role of ATMP in carbon steel” »

Work

How do Organic Phosphorus Compounds inhibit corrosion of oil pipelines?

Posted on January 16, 2024 By admin No Comments on How do Organic Phosphorus Compounds inhibit corrosion of oil pipelines?

Organic Phosphorus Compounds can inhibit corrosion of oil pipelines through several mechanisms: Formation of a protective film: Organophosphorus compounds have the ability to adsorb onto the metal surface and form a protective film. This film acts as a physical barrier, preventing corrosive substances from coming into direct contact with the metal. Complex formation: The phosphorus…

Read More “How do Organic Phosphorus Compounds inhibit corrosion of oil pipelines?” »

Work

Physical properties of antiscalant ATMP

Posted on January 15, 2024 By admin No Comments on Physical properties of antiscalant ATMP

The physical properties of the antiscalant Amino Trimethylene Phosphonic Acid (ATMP) can vary slightly depending on the specific product and manufacturer. However, here are some general physical properties associated with ATMP: Appearance: ATMP is typically a colorless or pale yellow liquid. It may also be available in powder or solid form. Odor: ATMP is odorless…

Read More “Physical properties of antiscalant ATMP” »

Work

Precautions for using corrosion and scale inhibitor ATMP

Posted on January 15, 2024January 15, 2024 By admin No Comments on Precautions for using corrosion and scale inhibitor ATMP

When using the corrosion and scale inhibitor Amino Trimethylene Phosphonic Acid (ATMP), it is important to follow certain precautions to ensure safe handling and optimal performance. Here are some precautions to consider when using ATMP: Personal Protective Equipment (PPE): Wear appropriate PPE, such as gloves, goggles, and protective clothing, when handling ATMP. This will help…

Read More “Precautions for using corrosion and scale inhibitor ATMP” »

Work

How do Organic Phosphorus Compounds inhibit corrosion in oilfield reinjection water systems?

Posted on January 15, 2024January 15, 2024 By admin No Comments on How do Organic Phosphorus Compounds inhibit corrosion in oilfield reinjection water systems?

Organic phosphorus compounds are commonly used as corrosion inhibitors in oilfield reinjection water systems. These compounds work by forming a protective film on metal surfaces, which helps to prevent corrosion. Here’s how organic phosphorus compounds inhibit corrosion: Passivation: Organic phosphorus compounds act as passivating agents that form a thin, protective film on metal surfaces. This…

Read More “How do Organic Phosphorus Compounds inhibit corrosion in oilfield reinjection water systems?” »

Work

What are the boiler deoxidizers?

Posted on January 15, 2024January 15, 2024 By admin No Comments on What are the boiler deoxidizers?

Boiler deoxidizers are chemicals used in water treatment to remove dissolved oxygen from the feedwater in boilers. Dissolved oxygen can cause corrosion and pitting in metal surfaces, which can lead to leaks and other problems in boiler systems. Deoxidizers work by chemically reacting with dissolved oxygen to remove it from the water before it enters…

Read More “What are the boiler deoxidizers?” »

Work

Registration matters required during PAA transportation

Posted on January 15, 2024January 15, 2024 By admin No Comments on Registration matters required during PAA transportation

Peracetic acid (PAA) is a hazardous substance that requires proper handling and transportation to ensure safety. Here are some registration matters that may be required during PAA transportation: United Nations (UN) Number: PAA is assigned a UN number, which is a four-digit code used to identify hazardous materials during transportation. The UN number for PAA…

Read More “Registration matters required during PAA transportation” »

Work

Introduction to the physical and chemical properties of ATMP

Posted on January 15, 2024January 15, 2024 By admin No Comments on Introduction to the physical and chemical properties of ATMP

Amino Trimethylene Phosphonic Acid, commonly known as ATMP, is a phosphonic acid-based organic compound. Here is an introduction to its physical and chemical properties: Physical Properties: Appearance: ATMP is usually a clear, colorless to pale yellow liquid. It can also be found in solid form as a white crystalline powder. Molecular Weight: The molecular weight…

Read More “Introduction to the physical and chemical properties of ATMP” »

Work

Posts pagination

Previous 1 … 48 49 50 … 131 Next

Categories

  • Biocide and Algicide
  • Built Scale & Corrosion Inhibitors and Pretreatment Filming Agents
  • Casual
  • Corrosion Inhibitors & Oxygen Scavenger
  • Corrosion Inhibitors & Oxygen Scavenger
  • Life
  • Phosphonates Antiscalants
  • Polycarboxylic Antiscalant and Dispersant
  • Reverse Osmosis Chemicals
  • Salts of Phosphonates
  • Salts of Phosphonates
  • Surfactant & Others
  • Uncategorized
  • Work

档案

  • December 2025
  • November 2025
  • October 2025
  • September 2025
  • August 2025
  • July 2025
  • June 2025
  • May 2025
  • April 2025
  • March 2025
  • February 2025
  • January 2025
  • December 2024
  • November 2024
  • October 2024
  • September 2024
  • August 2024
  • July 2024
  • June 2024
  • May 2024
  • April 2024
  • March 2024
  • February 2024
  • January 2024
  • December 2023
  • November 2023
  • October 2023
  • September 2023
  • August 2023
  • July 2023
  • June 2023
HEDP的车间

Recent Posts

  • Environmental regulations are tightening, consumer demand is growing, and the outlook for water treatment chemicals is promising.
  • Suggestions and Outlook for the Development of China’s Fine Chemical Industry
  • Issues and Challenges Facing China’s Fine Chemical Industry
  • Current Status of China’s Fine Chemical Industry Development
  • The reliability of transportation is also a key factor in selecting pharmaceutical partners.

Recent Comments

  1. admin on Is Food Additive Sodium Polyacrylate Harmful to Human Body

Copyright © 2025 Water treatment agent researcher.

Powered by PressBook WordPress theme