The specific formula of reverse osmosis dirt is usually determined by different suppliers and manufacturers based on their patented technology and R & D results, so the formulas of different products may be different. However, generally speaking, the recipe of reverse osmosis dirt may include the following main components:

Correspondent: The corrosion agent can reduce the corrosion of the metal ions in the water and reduce the generation of scaling. Common corrosion agents include organic phosphate, corrosion amine compounds, etc.

Differentians: Dispenses can disperse colloidal particles in water and suspension to prevent them from depositing on the surface of the RO membrane. Common dispersing agents include polyacrylamide and polyethylene amine.

Moisturizer: The cleaner has the ability to remove existing scaling and sediments to restore the efficiency of the RO film. Formulas of cleaner usually include weak acids, chelating agents and surfactants.

Polymer additives: Polymer additives can increase anti -pollution capacity on the surface of the RO membrane and reduce the deposition and scaling of colloidal particles. Common polymer additives include polyamide, polyvinyl alcohol, etc.

PH regulator: PH regulator is used to regulate the pH of water to ensure running the RO system within the appropriate pH range. This can be achieved by using acid or alkali.

It should be noted that the proportion and combination of specific formulas may be different due to product types, application areas and manufacturers. The exact formula is usually the commercial secrets of the supplier and may not be provided publicly. Therefore, when selecting and using reverse osmosis dirt, it is recommended to refer to the product description and technical information provided by the supplier, and follow the correct use methods and suggestions.

Work

Post navigation

Previous Post: What is cleaning pre -membrane
Next Post: Technical indicator of reverse osmosis dirt

Leave a Reply Cancel reply

You must be logged in to post a comment.

Categories

  • Biocide and Algicide
  • Built Scale & Corrosion Inhibitors and Pretreatment Filming Agents
  • Casual
  • Corrosion Inhibitors & Oxygen Scavenger
  • Corrosion Inhibitors & Oxygen Scavenger
  • Life
  • Phosphonates Antiscalants
  • Polycarboxylic Antiscalant and Dispersant
  • Reverse Osmosis Chemicals
  • Salts of Phosphonates
  • Salts of Phosphonates
  • Surfactant & Others
  • Uncategorized
  • Work

档案

  • May 2025
  • April 2025
  • March 2025
  • February 2025
  • January 2025
  • December 2024
  • November 2024
  • October 2024
  • September 2024
  • August 2024
  • July 2024
  • June 2024
  • May 2024
  • April 2024
  • March 2024
  • February 2024
  • January 2024
  • December 2023
  • November 2023
  • October 2023
  • September 2023
  • August 2023
  • July 2023
  • June 2023
HEDP的车间

Recent Posts

  • Is DDBAC/BKC toxic?
  • The main purpose of DDAC
  • Which is better, the solid form (sodium salt) or the liquid form of ATMP?
  • Storage method of antiscalant ATMP
  • How to distinguish the quality of HEDP

Recent Comments

  1. admin on Is Food Additive Sodium Polyacrylate Harmful to Human Body

Copyright © 2025 Water treatment agent researcher.

Powered by PressBook WordPress theme